6. Tuck the connectors and cable tie into the remote module
housing. Place backplate on the assembly and tighten the four
backplate screws using a size T-10 Torx screwdriver.
Important! Verify that the cable tie
and gel connectors are inside the
module housing and that the cable
extends out of the slot in the
backplate. Torque the backplate
mounting screws to 9 to 12 inch-
pounds.
Installing the Remote Module Cable
1. Insert the plug on the cable connected to the
module into the receptacle on the meter adapter
plate.
2. Tighten the threaded collar on the plug onto the American Meter interface receptacle. Verify that the
connection is hand-tight.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation