Caution: Do not strip the individual wires.
4. Connect the meter cable to the remote module wires using 3M gel-cap connectors following the American
RPM meter to remote module wire connection information and wiring diagrams.
Important! Use a crimping tool compatible with gel-connectors. Do not use
standard pliers for crimping gel-connects. For more information, see Using Gel-
cap Connectors to Complete Wiring Connections on page1.
Wire connection information
American meter wire Remote module wire
Black Blue
White White
Red Red
5. Insert the meter cable through the slot on the remote module backplate. Install a cable tie to the
meter cable wire below the meter cable insulation to provide strain relief.