Elster American Meter Mounting Instructions
1. Remove the meter's top plate by removing the two 5mm screws and
carefully prying up on the plate. The plate is secured with an O-ring seal.
Remove the O-ring from the plate.
Caution: If the O-ring is damaged during
removal, obtain a replacement from Elster
American Meter Co.
2. Look into the meter tower and find the meter switch lead and connector
(4-pin).
3. If the lead and connector are not visible or cannot be found, remove the
four 5mm mounting screws and the register cover. The meter switch lead
and connector will be visible inside the cover.
4. Feed the lead and connector into the register cover tower.
Note: Save any meter tags. You will re-install them
later in the installation process.
5. If you removed the register cover, replace the cover using the four (4)
5mm mounting screws.
6. Attach the 4-pin male connector on the Elster American Meter adapter plate to the 4-pin female connector
inside the meter's tower. The connectors will slide together and latch.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 36 of 91