Installation Guide

Table Of Contents
9. Enter the parameters shown in the Corrected
Pulse Output Setup section in the lower left of the
window.
10. Click Send All Changes.
11. Verify that all parameters are correct.
12. Click Disconnect.
Using Eagle Research Field Manager to Change the XARTU Corrector Settings
1. Open the Eagle Research Field
Manager from the Start menu or the
desktop shortcut.
2. Click Connect on the upper left
corner of the Field Manager window.
3. Select the following parameters:
Connection Type: Direct
Communications Port: Enter your computer's port number.
Baud Rate: Enter the baud rate for the XARTU-1 corrector.
4. Verify that the time and station name are correct.
5. Click View/Config.
Click OK
6. Click the Setup Parameters tab at the bottom of the parameters window.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 33 of 91