Installation Guide

Table Of Contents
A Connect to Remote window opens.
4. Select the following parameters:
Connection Type: Direct
Communications Port: enter your computer's port number
Baud Rate: enter the baud rate that displayed in Step 2.
5. Click OK.
6. Click View/Config.
The Field Manager window opens and displays the
settings for the current connection.
7. Click the Setup Parameters tab at the bottom of the parameters window. A parameters window opens.
8. Enable POut 5 (17, 18) and set the additional
parameters as required in the Uncorrected Pulse
Output Setup at the lower right of the window.
Important! If your
software does not have an
option to use POut for the
uncorrected pulse output,
contact Eagle Research to
get the correct software
version.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 32 of 91