4. Connect the red remote module wire to pin 4 of the K2
terminal port.
5. Twist the remote module's blue and white wires together and connect the twisted blue and white wires to
pin 5 of the K2 terminal port.
6. Plug the MTA battery connector from the battery pack into the VBAT1 connector to supply power to the
XARTU-1 corrector.
7. Close and latch the corrector door.
For XARTU-1 corrected reads:
8. With the XARTU door open, insert the flying leads from
the remote module into the compression connector on the
left of the corrector's housing.
9. Pull the lead wires through the compression
connector until there is adequate wire to reach the K1
terminal port.
a. K1
b. K2
c. K3
10. Tighten the compression connector.
11. Connect the red remote module wire to pin 1 on the K1 terminal port.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 30 of 91