5
Specific Meter Manufacturer Installation
This chapter provides the instructions to install the remote module to compatible meters.
Reference each section for compatible meters.
Eagle Research Meter Installation
This section provides the information to install the 500G remote module on the following
compatible Eagle Research correctors.
Meter model Meter notes Itron part number module notes
MPplus volume corrector
Pulse width:
70mS and 500mS off timing
Pulse output board required
ERG-7000-502
XARTU-1
volume corrector
Pulse width:
70mS on and 500mS off timing
Corrector must have Solid State
relays
Eagle Research Installation Overview
Installing the remote module to an Eagle Research volume corrector involves four tasks.
1. Programming or verifying that the volume corrector is set up to work with the remote module.
Programming requires a computer loaded with the Eagle Research Software and an Eagle
Research computer-to-volume corrector communication cable.
2. Connecting the module to the volume corrector.
Requires a wire stripper and flat-tip screwdriver sized to tighten the terminal connections on
the Eagle corrector.
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 26 of 91