Installation Guide

Table Of Contents
Programming Example
Endpoint programmed for 6 dial, 1000 cubic feet CCF.
1. Enter the initial index read. For this example, the initial read is 123456 where 6 = 600 cubic
feet. After the initial programming, an endpoint read will result in a reading of 1234560 where
the least significant digit is in 10's of cubic feet. Since counting is with a drive rate of 1000
cubic feet and the reading is transmitted in 10's of cubic feet, the last two digits of the reading
will not change.
2. Program the endpoint to 123456.
3. Read the endpoint. The result should be 1234560 with the zero added to put the reading in
10's of cubic feet.
4. Add one count. The result should be 1234660. Notice that the last two digits of 60 do not
change.
Mercury X-Blank Options
Endpoints (modules) can be programmed with one of the Mercury X-Blank options. There are 1,
2, 3, and 4 blank option available. Blank options are set up as a what-you-see-is-what-you-get
(WYSIWYG) configuration. The values are not set in cubic feet or cubic meter standards. The
Mercury X-Blank options are used in configurations where the system receives pulses from a
corrector or instrument that can change pulse values and has configurable display digits. The
Mercury-X Blank options allow users to program the endpoint to match the configuration of the
corrector or instrument.
Cellular 500G Module Remote Installation Guide 4 Programming
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 24 of 91