Installation Guide

Table Of Contents
4
Programming
Caution: You must program the module before use.
Programming Itron modules requires an understanding of:
Your meter's drive rate and the number of dials
The drive rate and number of dials is important for programming the module to count
correctly and roll over to zero at the correct time. For example, a four-dial, 2 cubic-feet
meter configuration will count two cubic-feet for each rotation and roll over to zero after
9999.99 where the ones place is equivalent to 100 cubic-feet.
How your system interprets the meter reading
Some systems modify the consumption reading with the collection software. Other times,
the billing system is used to make modifications. If modifications are made in both
systems, issues may cause consumption reading errors.
It is important to understand your system before the modules are programmed.
Program the module in OpenWay Riva Network Mode using a compatible programming device
loaded with FDM version 4.1 or higher.
Program the module in Mobile Mode using an approved programming device loaded with Field
Deployment Manager (FDM) software version 4.0 or higher.
Standard Configuration
Gas modules are capable of configurations that reduce battery life. Standard battery life is
based on the following configuration:
Hourly interval data
Interrogations of 3 times per day
60-second receiver wakeup
Five firmware downloads over the life of the module
Network management and security overhead set to default timing
RF at capacity (2,000 maximum per cell)
Average of one two-way command/response per week
Programming the Cellular 500G Module
Program the meter drive rate into the remote module using a compatible programming device.
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 21 of 91