4. Place the band clamp around the pipe. The band will
loosely wrap around the pipe.
a. Push the end of the band through the band clamp
screw assembly.
b. Turn the band clamp's screw assembly to fit into the
pipe bracket opening.
c. Tighten the clamp screw until the band clamp is
secure on the pipe.
5. Place the adapter plate on the pipe bracket with the
mounting lug at the top. The adapter plate screw bosses
fit into the pipe bracket recess.
6. Ensure that the adapter plate is positioned as shown
with the mounting lug (1) at the top.
a. Install the adapter plate on the pipe mounting bracket,
use the two shortest (½-inch) screws from the pipe
mount kit.
b. Place the mounting screws into the holes as shown
(2).
Tighten both screws in an alternating pattern to 9 to 12
inch-pounds torque.
7. Position the back of the remote module against the face of the adapter plate. The adapter plate
mounting lug must be positioned above the module mounting lug recess.
8. Push up on the module until the adapter plate mounting lug is as far as possible inside the module
mounting lug recess.
9. Align the module back-plate mounting holes with the
pipe mount adapter plate holes. Install the two one-inch
module mounting screws from the installation kit. Tighten
the module mounting screws evenly in an alternating
pattern. Tighten the screws to 9 to 12 inch-pounds torque.
Cellular 500G Module Remote Installation Guide 3 Mounting