Installation Guide

Table Of Contents
3
Mounting
This chapter provides the instructions to mount the remote module on a pipe or other flat vertical
surface (wall).
Standard Installation Options
Mount the remote module using the pipe mount or wall mount (flat vertical surface) procedure.
Pipe mount. Itron offers a pipe installation kit (CFG-0005-003) to mount the remote module
on a pipe.
Flat vertical (wall) mount. Installation using the wall mount option places the module on a
wall or other vertical surface.
Select the mounting option that will best work for your system. For example, your setup may
provide the location for a pipe mount but not a wall mount. The preferred mounting location is
near the meter or instrument, but some installations may require an extended cable length. For
example, your installation may require mounting the module around a corner to avoid RF
interference. The remote module supports cable lengths up to 300 feet with a recommended
one-splice limitation. Installers must mount the remote module in a vertical position with the label
directional arrow pointed upward.
Warning! Do not mount the remote module in an orientation other than vertical
(remote module label arrow pointed upward). Violating the mounting orientation
requirements may void the product warranty.
Upright vertical positioning is critical because:
The modules are optimized for communication and require upright mounting. Any other
mounting position could result in reduced RF performance.
The remote module tilt tamper sensor requires upright mounting. Any other mounting
position can cause issues with the module's tilt tamper detection.
Mounting on a Pipe
The following items are required to mount the remote module on a pipe.