Cellular 500G Module Remote Installation Guide xx xx ITRON INSTALLATION GUIDE 10 March 2021 815-0622-00 REV 000 Itron, Inc.
Cellular 500G Module Remote Installation Guide 10 March 2021 815-0622-00 Copyright © 2021 Itron, Inc. All rights reserved. Confidentiality Notice Confidential Information of Itron®, Inc., provided under nondisclosure obligations. The information contained herein is proprietary and confidential and is being provided subject to the condition that (i) it be held in confidence except to the extent required otherwise by law and (ii) it will be used only for the purposes described herein.
Contents Ce u l a l r5 0 0 GMo d u le Re mo te In s ta la o ti n Gu d i e 1 Co n te n ts 3 New in This Document 6 1 Important Safety and Compliance Information 7 U.S. and Canadian Patent Numbers 7 U.S.
Cellular 500G Module Remote Installation Guide 3 Table of Contents Operational Specifications 15 Device Firmware Functionality 15 Related Documents 15 Mounting 16 Standard Installation Options 16 Mounting on a Pipe 16 Completing the Installation 4 5 Adapter Plate Mounting Positions 19 Selecting and Installing On a Wall or Flat Vertical Mounting Location 19 Programming 21 Standard Configuration 21 Programming the Cellular 500G Module 21 Itron Programs and Software Variables 22 F
Cellular 500G Module Remote Installation Guide Table of Contents GE Oil and Gas Meter Installation 41 GE Oil and Gas Module Installation Overview 42 GE Oil and Gas Custom Mounting Options 43 GE Oil and Gas Mechanical and Wiring Installation Instructions 46 GE Oil and Gas Meter Programming and Requirements Notes 53 54 Honeywell Instrument Installation Honeywell Instrument Installation Overview 55 Honeywell Product Mounting Instructions 56 Honeywell Mechanical and Wiring Installation Instructi
Cellular 500G Module Remote Installation Guide Table of Contents New in This Document Revision REV 000 10 March 2021 Date Description March 2021 First date of publication. 815-0622-00 REV 000 Itron, Inc.
1 Important Safety and Compliance Information This section provides important information for your safety and product compliance. U.S. and Canadian Patent Numbers U.S. Patent Numbers ■ 4,614,945 ■ 4,753,169 ■ 4,768,903 ■ 4,799,059 ■ 4,867,700 Canadian Patent Numbers ■ 1,254,949 ■ 1,267,936 ■ 1,282,118 USA, FCC Part 15 Spectrum Compliance This device complies with Part 15 of the FCC Rules.
Cellular 500G Module Remote Installation Guide 1 Important Safety and Compliance Information harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ■ Reorient or relocate the receiving antenna. ■ Increase the separation between the equipment and receiver.
Cellular 500G Module Remote Installation Guide 1 Important Safety and Compliance Information Canada, ISED Spectrum Compliance Compliance Statement Canada Déclaration de Conformité This device complies with Innovation, Science and Economic Development Canada (ISED) licenseexempt RSS standard(s).
Cellular 500G Module Remote Installation Guide 1 Important Safety and Compliance Information ■ The lithium battery may cause a fire or chemical burn if it is not disposed of properly. ■ Do not recharge, disassemble, heat above 100° Celsius (212° Fahrenheit), crush, expose to water, or incinerate the lithium battery. ■ Keep the lithium battery away from children.
2 About the Itron Cellular 500G Remote Module The Cellular 500G remote modules are an IPV4/IPv6 open standards-based gas modules designed to be read under Itron’s multi-purpose OpenWay Riva Network Mode or by legacy Mobile Mode. In OpenWay Riva Network Mode, the Remote module offers firmware download, sub-hourly interval data, and extended data storage. In Mobile Mode, the Remote module operates identical to the 100G DLS Dataglogging Remote module.
Cellular 500G Module Remote Installation Guide 2 About the Itron Cellular 500G Remote Module (Optional) Hard to Read Mode The module transmits a high-powered RF message every 30 seconds. In Hard to Read Mode, the expected battery life decreases to 15 years in this mode. The hard to read mobile mode should only be used for exceptionally hard-to-read applications (such as meters installed on rooftops or in sub-basements).
Cellular 500G Module Remote Installation Guide 2 About the Itron Cellular 500G Remote Module ■ Supports writing data (in both manufacturing and by FDM) to the module to support future installation programming auditing. ■ Reading the auditing data is supported locally. ■ Auditing parameters include FDM User ID, number of dials, meter drive rate, unit of measure, count rate, rollover, and PComp. ■ Timestamping of auditing parameters. ■ Log access via COSEM only.
Cellular 500G Module Remote Installation Guide 2 About the Itron Cellular 500G Remote Module Important! Modules ordered pre-programmed with security injected and specified as Zero Touch Deployment require that the installer rotates the wriggler five (5) times to activate the module to join the network, if the module is installed in a location with little or no gas flow.
Cellular 500G Module Remote Installation Guide 2 About the Itron Cellular 500G Remote Module Operational Specifications Operational specifications Description Operating temperatures -40° to 158° F (-40° to +70° C) Operating humidity 5 to 95 percent relative humidity Data integrity Verified in every data message Device Firmware Functionality This section lists the remote module device firmware information and lists functionality by version.
3 Mounting This chapter provides the instructions to mount the remote module on a pipe or other flat vertical surface (wall). Standard Installation Options Mount the remote module using the pipe mount or wall mount (flat vertical surface) procedure. ■ Pipe mount. Itron offers a pipe installation kit (CFG-0005-003) to mount the remote module on a pipe. ■ Flat vertical (wall) mount. Installation using the wall mount option places the module on a wall or other vertical surface.
Cellular 500G Module Remote Installation Guide Itron part number CFG-0005-003 3 Mounting Description Pipe mount kit contents: ■ 2 band clamps ■ 2 tamper seals ■ 1 pipe bracket ■ 2 cable ties ■ 1 adapter plate ■ the following screws: 1. SCR-0215-001 (2) #8-16 x ½ inch slotted pan-head tapping screw, corrosion-resistant steel. Attaches the adapter plate to the pipe bracket. 2. SCR-0215-002 (2) #8-16 1-inch slotted pan-head tapping screw, corrosion-resistant steel.
Cellular 500G Module Remote Installation Guide 3 Mounting 4. Place the band clamp around the pipe. The band will loosely wrap around the pipe. a. Push the end of the band through the band clamp screw assembly. b. Turn the band clamp's screw assembly to fit into the pipe bracket opening. c. Tighten the clamp screw until the band clamp is secure on the pipe. 5. Place the adapter plate on the pipe bracket with the mounting lug at the top. The adapter plate screw bosses fit into the pipe bracket recess.
Cellular 500G Module Remote Installation Guide 3 Mounting 10. Insert the tamper seals. 11. Gather the excess module cabling into a loop and use the cable tie to secure the gathered cable to the pipe. Adapter Plate Mounting Positions Note: The notch at the top of the adapter plate (1) must always be at the top position. The following illustrations show the various mounting configurations. The adapter plate mounting screw locations are indicated (2).
Cellular 500G Module Remote Installation Guide 3 Mounting 1. Drill three pilot holes in the mounting surface. The drilled pilot holes for the two bottom screws must be on a horizontal line. a. 3 inches b. 1-11/16 inches c. 3-3/8 inches 2. Screw the top mounting screw into the top pilot hole drilled in step one, leaving enough of the screw protruding so the module lug recess on the back plate slides over the screw head and fits completely into the lug recess. Make adjustments as necessary. 3.
4 Programming Caution: You must program the module before use. Programming Itron modules requires an understanding of: ■ Your meter's drive rate and the number of dials – ■ The drive rate and number of dials is important for programming the module to count correctly and roll over to zero at the correct time. For example, a four-dial, 2 cubic-feet meter configuration will count two cubic-feet for each rotation and roll over to zero after 9999.99 where the ones place is equivalent to 100 cubic-feet.
Cellular 500G Module Remote Installation Guide 4 Programming 1. Verify that you have the correct programming mode (OpenWay Riva Network Mode or Mobile Mode [mobile high power mode, mobile/handheld mode, or hard-to-read mode]) for your application. 2. For all programming and Check Endpoint operations using a handheld computer, hold the handheld as close to vertical as possible. For best success, keep the handheld within six feet of the target module. 3.
Cellular 500G Module Remote Installation Guide 10 March 2021 4 Programming 815-0622-00 REV 000 Itron, Inc.
Cellular 500G Module Remote Installation Guide 4 Programming Programming Example Endpoint programmed for 6 dial, 1000 cubic feet CCF. 1. Enter the initial index read. For this example, the initial read is 123456 where 6 = 600 cubic feet. After the initial programming, an endpoint read will result in a reading of 1234560 where the least significant digit is in 10's of cubic feet.
Cellular 500G Module Remote Installation Guide 4 Programming Check Endpoint Functions The FDM Check Endpoint function triggers users to input the number of dials and drive rate if a Check Endpoint is requested for an endpoint programmed for 5, 6, or 7-dial meter configurations. The request to input the dial and drive rate information happens only if the system has more than one option using the same count rate and rollover variable enabled in their FDM business unit.
5 Specific Meter Manufacturer Installation This chapter provides the instructions to install the remote module to compatible meters. Reference each section for compatible meters. Eagle Research Meter Installation This section provides the information to install the 500G remote module on the following compatible Eagle Research correctors.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 3. Mounting the remote module. Select the mounting option appropriate for your installation. Mounting options include: – Wall mount on a sheet metal surface – Pipe mount using the Itron pipe mount kit CFG-0005-003 – Custom Eagle Research mounting option using the Eagle research mounting rail (Eagle Research part number 1010247.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 2. Insert tamper seals into the tamper seal mounting cups on the remote modules. 3. With the corrector facing forward, align the corrector mounting holes with the index drive mounting holes. 4. Insert the corrector's mounting screws in the front corrector and index mounting holes. Loosely tighten the front two mounting screws. 5.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation For corrected reads: 6. Connect the twisted blue and white wires to terminal 15 on the MPplus terminal block. 7. Connect the red remote module wire to terminal 16 on the MPplus terminal block. 8. Close and latch the MPplus corrector door. Connecting to the XARTU Corrector For XARTU-1 uncorrected reads: 1.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 4. Connect the red remote module wire to pin 4 of the K2 terminal port. 5. Twist the remote module's blue and white wires together and connect the twisted blue and white wires to pin 5 of the K2 terminal port. 6. Plug the MTA battery connector from the battery pack into the VBAT1 connector to supply power to the XARTU-1 corrector. 7. Close and latch the corrector door. For XARTU-1 corrected reads: 8.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 12. Twist the remote module's blue and white wires together. 13. Connect the twisted blue and white wires to terminal 2 on the K1 terminal port. Eagle Research Corrector Programming and Requirements Notes Important! This information is subject to change without notice. Refer to the Eagle Research product documentation to verify the most current programming and configuration information for the 500G remote module.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation A Connect to Remote window opens. 4. Select the following parameters: ■ Connection Type: Direct ■ Communications Port: enter your computer's port number ■ Baud Rate: enter the baud rate that displayed in Step 2. 5. Click OK. 6. Click View/Config. The Field Manager window opens and displays the settings for the current connection. 7. Click the Setup Parameters tab at the bottom of the parameters window.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 9. Enter the parameters shown in the Corrected Pulse Output Setup section in the lower left of the window. 10. Click Send All Changes. 11. Verify that all parameters are correct. 12. Click Disconnect. Using Eagle Research Field Manager to Change the XARTU Corrector Settings 1. Open the Eagle Research Field Manager from the Start menu or the desktop shortcut. 2.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation The Meter Setup and Accumulation Multipliers window opens. Set up the meter and accumulation multipliers as appropriate for your installation. 7. Enable K2 (4, 5, 6) and set additional parameters are required in the Uncorrected Pulse Output Setup section in the lower right of the window. 8.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation follow the installation procedures in this section. Meter model Meter notes 10 Metric (10B) Itron part number Originally manufactured by Metric Metal Works ERG-7000-501 Meter must have factory-installed pulser with connector output. Purchase correct cable interface from manufacturer.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Elster American Meter Mounting Instructions 1. Remove the meter's top plate by removing the two 5mm screws and carefully prying up on the plate. The plate is secured with an O-ring seal. Remove the O-ring from the plate. Caution: If the O-ring is damaged during removal, obtain a replacement from Elster American Meter Co. 2. Look into the meter tower and find the meter switch lead and connector (4-pin). 3.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 7. Carefully push the connectors and wires into the meter tower housing. 8. Lubricate the O-ring with O-ring lubricant and install the O-ring on the adapter plate. Insert the adapter plate into the tower and tighten the two 5 mm screws.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Caution: Do not strip the individual wires. 4. Connect the meter cable to the remote module wires using 3M gel-cap connectors following the American RPM meter to remote module wire connection information and wiring diagrams. Important! Use a crimping tool compatible with gel-connectors. Do not use standard pliers for crimping gel-connects.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 6. Tuck the connectors and cable tie into the remote module housing. Place backplate on the assembly and tighten the four backplate screws using a size T-10 Torx screwdriver. Important! Verify that the cable tie and gel connectors are inside the module housing and that the cable extends out of the slot in the backplate. Torque the backplate mounting screws to 9 to 12 inchpounds.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Galvanic Gas Micro Installation This section describes installation to Galvanic compatible correctors. Meter model Meter notes Must select 2 pulses/second from pulse output on the output frequency menu. Itron part number ERG-7000-503 module notes module cut cable requires customersupplied cable capable of terminating the module white and blue wires at the meter interface.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Galvanic Mechanical and Wiring Installation Instructions GAS Micro wiring connections GAS Micro corrector P13 connection 100G module wires Pulse output1-C C1 Blue/white Pulse output1-E C2 Red Pulse output2-E C3 Pulse output2-C C4 Programming the Galvanic Gas Micro Electronic Volume Corrector For more information about programming the Galvanic Gas Micro Electronic volume corrector, see the GAS MICRO Opera
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Meter model Meter notes Integral Micro Corrector IMC/W2 Itron part number Electronic volume corrector for Series A (LMMA) and Series B (rotary meters). Must be meter firmware version 1.94 or earlier. Pulse width must be set for 125ms. ERG-7000505 Pulse width must be set greater than 100ms. Firmware version 1.71 or earlier.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation – Wall mount on a sheet metal surface – Pipe mount using the Itron pipe mount kit CFG-0005-003 – Custom GE Dresser mounting • D800/D1000 mounting solution requires the following materials • (1) 8-32 x ½" screw • (2) 8-32 x ¾" screws • (3) 8-32" Kep nuts 5. Programming the remote module. Programming requires an Itron programming device (for example, an FC300SR).
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation GE Oil and Gas IMC/W2, or MC2 with the GE Mounting Bracket Kit Note: This mounting option requires that you follow the installation instructions to attach the meter maufacturer cable prior to completing this mounting option. This configuration requires the GE mounting bracket kit available from GE Oil and Gas (GE part number 057783-000). The kit includes the listed materials.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 3. Secure the bottom 500G remote module mounting holes over the two 8-32 x 3/4-inch screws with the remaining two 8-32 nuts. 4. Insert the #10 spacers into the four mounting holes on the back of the IMC\W2.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 5. Secure the module/bracket assembly on the IMC\W2 using four module/mounting bracket screws (M6 x 20 mm). Install tamper seals as required. 6. Connect the cable to the pulse output on the IMC/W2 or MC2. GE Oil and Gas Mechanical and Wiring Installation Instructions This section describes mechanical installation to the GE Oil and Gas meter and wiring connections. 10 March 2021 815-0622-00 REV 000 Itron, Inc.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation D800/D1000 Wiring and Installation 1. Loosen and remove the two screws holding the mounting brackets to the meter. 2. After the brackets are removed, the pulse output cable is visible. 3. Loosen the cable gland and pull the cable out until it extends 7.5 to 8" out of the cable gland. 4. Tighten the cable gland. Do not use a pliers or wrench to tighten the cable gland. 5. Rotate one bracket.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 6. Attach the brackets to the meter using the previously removed screws. 7. Splice the meter pulse output wires to the module wires using gel cap connectors. Follow the wire connections for the D800/D1000 to module wire connections below. Note: Use a crimping tool compatible with gel-connectors. Details on using the crimping tool are included in the mounting installation section of this document.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 10. Carefully fold the module wires into the module's housing. Do not pinch the wires of gel connections between the housing and the backplate. 11. Install the four back plate screws using the T-15 Torx screws supplied with the module. 12. Route the cable through the channel in the backplate standoffs. 13.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 15. Install the bottom two mounting screws and Kep nuts. Tighten the three mounting screws in an alternating pattern. 16. Install the supplied red tamper seals over the bottom mounting screws on the remote module. GE Oil and Gas Meters With Pulse Output Wiring These instructions describe B3 series, LMMA series, IMC, IMC/W2, MC2, and Series ES3 and ETC wiring connections.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Note: Use a crimping tool compatible with gel-connectors. For information about crimping the connections, see Using Gel-cap Connectors to Complete Wiring Connections on page 1. The same process is used for wiring cables to the module. Each meter or cable may have different wire colors and wiring instructions. See the specific wiring configuration for your product.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Wiring for direct connection to the IMC/W2 3. After completing the wiring connections, install a cable tie to the meter cable just below the exposed colored lead wires on the cable insulation. Remove the excess cable tie using a hand-held side-cutter pliers. The cable tie performs as a cable strain relief to mitigate the risk of destructive tension on the lead wires. 4.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation GE Oil and Gas Meter Programming and Requirements Notes GE MeterWare software is used to configure the module's index settings. Important! This information is subject to change without notice. Refer to the GE MeterWare product documentation to verify the most current information about programming and configuring the corrector for use with the remote module. 1.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Honeywell Instrument Installation Note: This meter is compatible only with devices running on the OpenWay Riva network. This section provides installation instructions for the remote module on the following compatible Honeywell Instruments. Meter model Mini-AT Meter notes Module type Itron part number Pressure and temperature electronic volume instruments. Instruments must have a Form A board.
Cellular 500G Module Remote Installation Guide Meter model 5 Specific Meter Manufacturer Installation Meter notes Module type Itron part number module notes Temperature Compensating Index. TCI must have a Form A board, Form C is NOT supported. Item #56 Pulse Scaling Factor must be 2.0. Compatible TCI firmware versions are 1.06, 1,07, and 1.10. 500G remote ERG-7000-502 The -502 module has a 5' cable and is used when longer cabling is required. This module will return the cut cable tamper.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Honeywell Product Mounting Instructions Two Remote Modules Mounted On a Honeywell Mini-Max Instrument 1. Place the Honeywell Instrument volume corrector in shutdown condition and disconnect all power from the Mini-Max main board. 2. Remove the battery pack from the volume corrector and set it aside. 3. Remove the four screws from the main board and the board from the enclosure. Set the board aside. 4.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation to ensure a secure fit. c. Install the two bottom screws in an alternating fashion. 8. Mount the module for uncorrected pulse outputs on the right bracket mounting space. a. Insert three #8-32 x 1/2-inch screws in a triangular pattern. Install the top screw so the head of the screw is approximately 1/8-inch from the mounting bracket surface. b.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Connecting to a Honeywell Mini-AT, Mini-Max, or EC-AT With Itron remote modules, utilities can receive corrected and uncorrected consumption values by installing two modules. The module for corrected reads is attached to the corrector's pulse output. The module for uncorrected reads is attached to the input switch board.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 4. Strip ¼-inch individual wire insulation from the red, white, and blue lead wires. a. Count enabling wire (pulsed ground reference) b. Count sensing wire (high impedance positive reference) c. Cut cable sensing wire (positive return) 5.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Ya terminal White* *Twist the blue and white module wires together before connecting them to the Mini-Max board. Tighten the terminal connection securely. 7. Connect the uncorrected module wires to the Input Switch Board UNC. VOL following the table below. Uncorrected module connections Mini-Max input switch board unc. vol.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation to ancillary devices. Loose wires are located inside the gray adapter plate behind the black strain relief fitting. Strain relief fitting Honeywell TCI strain relief tether Backplate black fitting with loose cable wires (Honeywell part number 22-1929) Completing the Connections 1. Connect the remote module to receive TCI pulse readings.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Yellow Red Blue (alarm) Blue Channel B TCI module wire White White Green Red White Blue 7. Insert one unterminated wire into an opening of a gel-connector (six gel-connectors were included with the TCI). 8. Insert the appropriate field cable wire into the other gel-connector opening. 9. Verify that both wires are fully inserted into the gel-connector prior to crimping.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Honeywell Software Settings 1. Connect the interface cable from the Honeywell instrument to a PC loaded with the MasterLink SQL software. 2. Open the MasterLink SQL software. The software opens and reports a "Not Connected" status. The Site List window automatically opens after the software detects an instrument. 3. Select the Honeywell instrument type from the Instrument List on the right of the screen.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation A Change Item pop-up provides the interface to change the setting. 7. Enter the correct setting. Click Save. 8. Confirm that all settings match the settings required for the module connected to the Honeywell Instrument. For more information, see compatible modules listed in Honeywell Instrument Installation on page 54.
Cellular 500G Module Remote Installation Guide Instrunmen t- Pulse Output Options 5 Specific Meter Manufacturer Installation Channel A Corrected Volume Channel B Uncorrected Volume Channel C Pulse Output Spacing #56 #57 #58 #115 #93 #94 #95 #1014 #1015 Itron 100G Itron 100G Terminal Board Connections / Wiring Wiring 2=2.
Cellular 500G Module Remote Installation Guide Meter model 5 Specific Meter Manufacturer Installation Meter notes Itron part number Notes #3 flat-face meter 400 Front-mount index ERG-7000-501 Requires a thicker gasket for magnet hub to clear index box. 1-hole gasket: FAB0014-001 2-hole gasket: FAB0014-002 4-hole gasket: FAB0014-003 675, 1000 National Meter Installation National/Lancaster meters are compatible with remote module with an encoder cable.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Romet Meter Installation This section describes installation for Romet meters and correctors compatible with Itron remote modules. Meter model RM Series STD CTR 600-5600 Meter notes Meter must have factory-installed pulser with connector output. Purchase cable interface from manufacturer.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 2. Connecting the module to the corrector. Installation requires the following materials.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Romet ECM2 to remote module mounting option 2. Insert the mounting screw fitted with the three lock washers. Two lock washers are used as spacers (as shown). 3. Attach the mounting plate to the meter. Insert the mounting screw where the module screw was removed. Torque the mounting screw to 5-7 ft.lbs. to secure the plate to the Romet meter. 4.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 1. Remove the module backplate (4 screws) to expose the module lead wires. The backplate and screws will be reinstalled on the module later in this procedure so store them (temporarily) in a safe, secure place. 2. Insert the lead wires from the module into new 3M gel connectors (Itron part number CON-0023-001) together with the lead wire from the meter cable (see wiring connections). 3.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Connection Corrected count Cut Cable Alarm Romet cable module Green Blue Note: The pigtail cable is the cable extruding from the back of the AdEM corrector. You must select the pigtail cable at the time the AdEM corrector is ordered.
Cellular 500G Module Remote Installation Guide Cable pin 5 Specific Meter Manufacturer Installation module wire Corrected Uncorrected Alarm E White and blue F Red Romet Cable Number 34-125-42 Cable pin module wire Corrected Uncorrected A White and blue B Red Alarm C White and blue D Red E White and blue F Red Romet cable number 34-125-43 Cable pin module wire Corrected Aux CC A White and blue B Red C White and blue D Red Alarm E White and blue F Red Romet Cable Numb
Cellular 500G Module Remote Installation Guide Cable pin 5 Specific Meter Manufacturer Installation module wire Aux CC D Red E F Romet Cable Number 34-125-45 Cable pin module wire Corrected Uncorrected A White and blue B Red C Alarm White and blue D Red E White and blue F Red Romet Cable Number 34-125-50 Cable pin module wire Corrected Uncorrected 1 Alarm Red 2 White and blue 3 White and blue 4 Red 5 Red 6 White and blue Romet Cable Number 34-125-51 Cable pin module w
Cellular 500G Module Remote Installation Guide Cable pin 5 Specific Meter Manufacturer Installation module wire Correct 3 Uncorrected White and blue 4 5 Aux CC Red Red 6 White and blue 4. After the wire connections are completed, install a cable tie to the meter cable just below the exposed colored lead wires on the cable insulation. 5. Remove the excess cable tie using a hand-held side-cutter pliers.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Important! Verify that the cable tie and gel connectors are inside the module housing and the cable extends out of the slot in the backplate. Torque the backplate mounting screws to 9 to 12 inch-pounds. 8. Install the module on the wall or a pipe using the pipe installation kit (Itron part number CFG-0005003) or install the module on the Romet AdEM meter using the Romet mounting bracket (Romet part number 46-444-2).
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 3d. Confirm that the meter was added to the Phone Book. 3e. Set up the corrected or uncorrected parameters. 3f. From the Talk to Unit tab, select Setup > Default. 3g. Set the following Default Setup Group parameters: ■ Enter the desired Cor. Volume Unit parameter. Set Cor. Pulse Volume to the same number of units. ■ For Output Pulse Spacing, enter the largest number over 285mS that works for your application.
Cellular 500G Module Remote Installation Guide Meter model 5 Specific Meter Manufacturer Installation Meter notes Sonix meters are pulse output registers which are programmed by Sensus software. Proper pulse output options and display options must be selected. Itron part number Module notes ERG-7000-503 Sonix pulse output 12, 16, 25, 57 (Metric) 600, 880, 2000 (cubic foot) Sensus Meter Installation Overview Installing the remote module to a Sensus meter involves the following tasks: 1.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation 1 Top anchor screw positions 2 Bottom anchor position for the module U-shaped mount Order the correct Sensus Sonix direct mount bracket for your installation requirements from Sensus North American Gas Customer Service. (Brackets and mounting hardware are ordered separately).
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation Sensus Meter Mechanical and Wiring Installation Instructions Sensus Sonix meters provide a standard Form A electronic pulse output compatible with the remote module. You may connect the Sensus Sonix meter to the remote module using the pulse output cable or you can directly mount the remote module to the meter.
6 Diaphragm Meter Installation This chapter provides the instructions to install remote modules (Itron part number ERG-7000501 with 2.5-foot cable and encoder) on diaphragm gas meters where a direct mount module is not possible.
Cellular 500G Module Remote Installation Guide Part Number 6 Diaphragm Meter Installation Description ERG-7000-501 Cellular 500G remote module with 2.5' encoder cable CFG-0081-001 Remote mount encoder kit 013-1723-112 1. acetone applicator stick 2. tamper seals 3. cable ties 4. mounting screws 5. magnet hub spacer 6. magnet hub Encoder spacing tool. Use the Encoder Spacing Tool to ensure that the encoder mounts the correct distance from the magnet hub on the meter index.
Cellular 500G Module Remote Installation Guide 6 Diaphragm Meter Installation Module Mounting For remote module mounting with the diaphragm meter, see Mounting on page 16. Diaphragm Meter Mechanical and Wiring Installation Instructions Caution: The remote module encoder must be installed at temperatures between 40° and 95°F to ensure proper adhesion. 1. Remove the diaphragm meter index cover and index.
Cellular 500G Module Remote Installation Guide 6 Diaphragm Meter Installation 4. Briefly place the magnet side of the magnet hub into the curved indentation in the encoder as shown in the illustration. Remove the magnet hub from the encoder and set it at least one inch away from the encoder. 5. Use an module programming device to read the remote module. If this reading is higher than the reading taken after the index was removed, the remote is counting and working properly.
Cellular 500G Module Remote Installation Guide 6 Diaphragm Meter Installation 7. Align the pointer (1) on the top of the magnet hub and the notch (2) in the side of the magnet hub with the needle (3) of the meter drive rate dial. 8. Press the magnet hub down over the hub spacer as far as possible. The bottom of the hub spacer may touch the index face. Turn the dial after magnet hub installation to verify that the index dial functions with a smooth, easy rotation. 9.
Cellular 500G Module Remote Installation Guide 6 Diaphragm Meter Installation 11. Tilt the acetone stick vertically with the applicator foam end down. Squeeze the acetone stick on the black dot until the packet inside the pen breaks. Continue to hold the pen in a vertical position until the acetone wicks into the foam applicator end. Apply a thorough coat of acetone to the index where the encoder will be installed. Do not touch the area where the acetone was applied before the encoder is installed. 12.
Cellular 500G Module Remote Installation Guide 6 Diaphragm Meter Installation 15. Remove the encoder spacing tool and lay the index on a flat, horizontal surface to reduce strain on the encoder cable. 16. Program the index reading (with the encoder mounted) into the remote module. Read the remote module and verify that the reading matches the read programmed into the remote module. 17. Use the correct replacement gasket for your meter's index.
Cellular 500G Module Remote Installation Guide 6 Diaphragm Meter Installation 20. Remove the protective backing on the replacement gasket to expose the adhesive side of the gasket. Align the gasket (1), encoder cable (2), and cable tie (for strain-relief) (3) on the meter as shown. Caution: Route the encoder cable inside the index cover to provide strain relief (minimize pulling or twisting on the encoder).
Cellular 500G Module Remote Installation Guide 6 Diaphragm Meter Installation Programming and Requirements Notes for Diaphragm Meter Installations For remote module programming, see Programming on page 21. Residential Module Programming Notes The module is programmed based on the meter's drive rate. Take note of the index drive rate shown on a lower dial on the index. Elster American meter index drive rates are either 1-cubic foot, 2-cubic feet or 0.05 cubic meters (not shown below).
7 Using Gel-cap Connectors to Complete Wiring Connections This section provides the instructions to complete remote module to meter wiring connections. Gel-cap connections require: ■ E-9R 3M gel-cap crimping tool ■ 3M gel-cap connectors (Itron part number CON-0023-001) 1. Push the two wires into the connector as far as possible. Caution: Do not strip insulation from the ends of the wires before inserting them into the connector. 2.
Cellular 500G Module Remote Installation Guide 7 Using Gel-cap Connectors to Complete Wiring Connections 4. The connector is properly crimped when the top of the moveable yellow center (1) is flush with the top of the connector body (2). Warning! Crimping the connector forces sealant out of the connector. The sealant protects the inside of the connector against insects, moisture, or other contaminants. The sealant may cause minor eye and skin irritation. Avoid eye contact.
8 Optional Sealant Application Instructions In areas where insect intrusion is a problem, Itron recommends an optional sealant to help keep insects out of the module housing. The Itron-tested and approved sealant (Itron part number ADH-5106-000) is used to seal gaps in remote module installations that can allow insect intrusion. 1. Prepare the module for the sealant by verifying the application area is clean and dry. Warning! Apply sealant in a wellventilated area. 2.