3. Wrap the entire piece of electrical tape around the Cellular 500W cable near the Cellular
500W .
4. Beginning over the installed electrical tape, twist the Itron cable armor onto the Cellular
500W cable using a right-handed twist.
Important! You must twist—not wrap—the cable armor onto the Cellular 500W
cable. Wrapping the cable armor can cause the stainless steel jacket to warp.
You must begin twisting the cable armorover the portion of the cable protected
by the electrical tape. If you do twist the cable armor onto the Cellular 500W
cable on the unprotected portion of the Cellular 500W cable, you could damage
the module's cable. A cut cable could cause a Cellular 500W or register
communication failure.
5. Continue to twist the cable armor onto the Cellular 500W cable until the cable armor
covers the entire cable.
6. Remove any leftover materials from the customer premises. Discard or recycle leftover
materials.