Installation Guide

6. Connect the Cellular 500W wires to the register screw terminals following the Cellular
500W to the Elster/AMCO meter register wire connections. After the wires are connected,
carefully tuck the connectors into the Cellular 500W housing. Tighten all screws securely.
Caution: Install the wires around the screws in a clockwise direction (as shown)
or the wires may come out from under the screw heads as you tighten them.
Also, verify that the wire insulation is NOT compressed under the screw head, or
the wire may not make good contact.
7. Install the module and mounting bracket on the meter register adapter collar.
8. Replace the hollow pin (1) you removed in step 1.
To direct mount to a Badger Direct Mount Register
Note: Verify you have a Badger meter with a register designed for direct mount remote
modules. Check the part number on the label to verify the module matches the meter.
Always install the module with the arrow on the housing pointing upward. The register may
or may not be mounted on the meter when performing the following steps.
Cellular 500W Remote Module Installation Guide 3 Setup and Installation
October 11, 2021 815-0618-00 REV 000 Itron, Inc. Page 25 of 44
DRAFT