To direct mount on the ABB Scancoder, InVision, or Digital Direct Mount
Note: Verify that you have an Elster/AMCO meter with a register designed for direct
mount Cellular 500W . Always install the Cellular 500W right side up with the arrow on the
housing pointed upward. The register may or may not be mounted on the meter when
performing the following steps.
1. Push the hollow pin (1) completely out of its location and separate the Cellular 500W
mounting bracket (2) from the meter register collar (3).
2. Strip 0.5 inches of insulation from the end of the brown, gray, and yellow wires.
3. Place the Cellular 500W on the mounting bracket and route the yellow, gray, and brown
wires through the opening.
Note: A gasket is not required.
4. Install four Torx-head mounting screws (SCR-0010-005).
5. Hand-tighten each screw.
Cellular 500W Remote Module Installation Guide 3 Setup and Installation
October 11, 2021 815-0618-00 REV 000 Itron, Inc. Page 24 of 44