Installation Guide

disconnect valve provides the ability to remotely open (reconnect) the valve.
Restricted. The water is restricted and flowing at the configured installation flow.
The Remote Disconnect Valve connects to the pit module's orange, blue, and purple/white
wires.
Itron Cable Armor Installation
The Itron cable armor provides a layer or protection for the module's cable jacket. Itron cable
armor is available in five-foot sections.
This section describes the procedure for installing Itron cable armor in a field installation.
Warning!Use caution when you are installing the cable armor.
Itron cable armor is stainless steel and may have sharp edges.
If you remove the inline connector from the pit module to install the cable armor, you must use an
Itron handheld to reprogram the pit module using FDM Endpoint Tools.
Perform a Check Endpoint function (with FDM Endpoint Tools) after you reprogram the pit module
to verify communication with the meter register.
Installing the Cable Armor
1. Remove the pit module from the pit.
Note: If it is possible in your field installation, keep the pit module connected to the
register.
2. Cut a two to three inch strip of electrical tape.
3. Wrap the entire piece of electrical tape around the pit module cable near the inline
connector.
Cellular 500W Module Pit Installation Guide 4 Accessory Installation
October 13, 2021 815-0617-00 REV000 Itron, Inc. Page 31 of 40
DRAFT