Pulser-type Register Connections
Pit module connections are made by the meter manufacturer for pulser-type registers. This
information describes those connections.
Caution: Itron recommends pit module connections be completed using the inline
connector. In rare instances, if a spliced connection is made, the Itron splice kit must
be used (Itron part number OEM-0034-002). For more information, see Completing
Gel-cap Connections Using the Itron Splice Kit on page 34
Module wire color
Black White
Register screw color designator
Badger RTR (3-wire) Black Green
Badger RTR (2-wire) Black No connection
Badger M5000 Mag Meter Black terminal: Out 1- White terminal: Out 1+
Cadillac Meter CMAG/EMAG Magnetic Flow COM DO1/DO2
Elster Digital Green Red
Elster V100T Red Blue
■ Itron (Actaris)
■ Flostar (2-wire)
■ Cyble Sensor
Remaining wire must be connected to both ERT module wires
Krohne IFC Term H Term B
RG3 Tomahawk Black Green
Sensus PMM Black Bare
Cable Extension
Order the 25 foot inline connector extension cable assembly (CFG-0151-404) to extend the pit
module's cable.
Operation Verification
Use one of the following handheld computers to verify data consumption:
■
FC300SR handheld computer
■
Itron Mobile Radio connected to a user-supplied computer or Bluetooth device
Cellular 500W Module Pit Installation Guide 2 Initialization, Connection, and Programming
October 13, 2021 815-0617-00 REV000 Itron, Inc. Page 16 of 40