Installation Guide
Table Of Contents
- Cellular 500W Module Pit Installation Guide
- Contents
- New in This Document
- 1 Introduction
- 2 Initialization, Connection, and Programming
- 3 Cellular 500W Pit Module Installation
- 4 Accessory Installation
- 5 Completing Gel-cap Connections Using the Itron Splice Kit
- A Troubleshooting
- B Important Safety and Compliance Information
–
Audit Mode remains active for 30 days and then reverts to the initial programmed
mode.
–
Audit Mode is intended to be used once.
■
Run Mode
–
Pit module normal operation mode.
–
The Cellular 500W Pit Module transmitted message is dependent on its factory
settings or setting programmed with FDM for standard consumption messages
(SCM+).
–
For SCM+ (Mobile), the pit module default bubble-up rate is 10 seconds.
■
Quiet Mode
–
Meter manufacturers can configure the pit module for Quiet Mode after initializing and
direct mounting the pit module in the factory.
–
The pit module awakens from Quiet Mode and enters run mode in one of the following
ways:
•
The pit module detects consumption at the top of the hour (last hourly interval is
greater than 1 or less than -1).
•
The pit module receives a two-way command (for example, a Read Endpoint
using FDM software).
Battery Life
The Cellular 500W Pit Module is powered by a single non-replaceable, long-life lithium
batteries and has an expected battery life of 20 years, dependent on use case.
Low Battery
The Cellular 500W Pit Modules include a low battery indicator that helps utilities proactively
plan and manage field module replacements.
Events and Alarms
The events and alarms available to a Cellular 500W Pit Module vary based on the mode it is
operating in.
Mobile Mode
Extended Alarm Flag
This is retrievable with two-way communication.
Cellular 500W Module Pit Installation Guide 1 Introduction
October 13, 2021 815-0617-00 REV000 Itron, Inc. Page 10 of 40