User's Manual

2.4ZR OpenWay Range Extender Configuration and Installation
TDC-0832-001 2.4ZR OpenWay® Range Extender Installation Guide 13
Proprietary and Confidential
To set up and verify the radio link to the gas module
1. Go to the gas meter with the 2.4GZ OpenWay gas module and use the Itron magnet to activate the gas
module's radio joining process. Refer to the 2.4GZ OpenWay Gas Module Installation Guide - Direct
Mount or 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount for complete instructions.
2. After you establish a connection between the gas module and the range extender, return to the range
extender and verify the signal quality. The connection status with the last joined gas module is indicated
by the blink pattern of the G LED. The G LED repeats a blink pattern every thirty seconds for the duration
of the installation time period.
LED
Number of
blinks
Definition
Action
G
1
Poor signal quality.
Move the range extender to a more suitable location (see
Selecting a Mounting Location on page 10) and repeat
Linking to a CENTRON Meter on page 11.
G
2-5
Acceptable signal quality.
No action is required.
If the signal quality is two blinks or better, an acceptable
radio link is established between the range extender (at
its temporary mounting location) and both the
CENTRON meter and the gas module.