User's Manual Part 2
Diaphragm Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 59
Proprietary and Confidential
Installing the 2.4GZ OpenWay Remote Mount Gas Module
The 2.4GZ OpenWay remote mount gas module mounts on a pipe using the Remote Mount Installation Kit
(Itron part number CFG-0005-003) or a vertical flat (wall) surface. Always mount the 2.4GZ OpenWay
remote mount gas module with the printed label right-side-up (arrow pointing up -1), and the encoder wires
(2) and tamper seals (3) at the bottom, as shown.
Caution Vertical mounting position is important to maximize RF performance. You can mount a
2.4GZ OpenWay remote gas module with the module's label arrow pointing up or down,
dependent upon the application as noted in the relevant section of this installation manual. The
module's arrow must never point to either side. The module's tilt tamper functionality is designed
to operate with the module installed vertically. The 2.4GZ module's tilt tamper will operate with the
label arrow pointed up or down. The module's tilt tamper will not operate with the module installed
horizontally (the label arrow pointed to either side).
Note The occurrence of false tampers may increase on inverted 2.4GZ modules installed in high vibration
areas.