User's Manual Part 2
Sensus Sonix Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 93
Proprietary and Confidential
To direct-mount the 2.4GZ OpenWay remote mount gas module on the Sonix meter
1. Place the module mounting bracket over the inlet or outlet pipe fitting on the Sonix meter. (The default
position is over the inlet connection - left side connection looking at the meter front.)
2. Remove the four module backplate screws and turn the backplate so the module mounting screw holes are
to the top of the module (the arrow on the module label must point up). Secure with the four module
backplate screws previously removed.
3. Slide the mounting lug (now on the bottom of the module) over the bottom anchor. Insert the two top
module mounting screws and tighten in an alternating fashion.
Connecting the 2.4GZ OpenWay Remote Mount Gas Module to a Sensus
Sonix 600 or 880 Meter
The 2.4GZ OpenWay remote mount gas module provides RF-based data collection for the Sonix 600 or 880
meter.
To wire the 2.4GZ OpenWay remote mount gas module to Sonix 600 and 880 meters
Connect the Sonix 600 or 880 meter to the 2.4GZ OpenWay remote mount gas module following the
wiring diagram below.