User's Manual Part 2
Electronic Instrument Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 54
Proprietary and Confidential
6. There are two options to connect the 2.4GZ remote gas module to Dresser ROOTS to the IMC\W2:
1. For the Amphenol connector: plug the connector from the Itron endpoint to the IMC\W2 volume
input connector.
2. For the cable gland or conduit fitting:
a. Route the cable from the 2.4GZ OpenWay remote mount gas module through the IMC\W2 cable
gland/conduit connector.
To receive uncorrected reads: connect the red wire to the terminal block 3 (TB3 telemetry output)
GND1 (ground) position (B). Connect the white and blue wires to the pulse output 1 position (A).
To receive corrected reads: connect the red wire to the GND 2/3 (ground) TB3 telemetry output
position (C). Connect the white and blue wires to the pulse output 2 position.
b. Tighten the cable gland fitting around the cable. Apply 15 inch-pounds torque.
Note 2.4GZ OpenWay remote mount gas modules using the flying lead cable assembly (Dresser
ROOTS
®
part number 055018-700) are factory wired to terminal block 3 (TB3) according to IMC\W2
pulse output default configuration. Consult the customer specification for other wiring configurations.