User's Manual Part 2
Dattus Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 86
Proprietary and Confidential
After the meter cover and bracket are replaced on the meter, the 2.4GZ OpenWay remote mount gas module is
connected to the pulse output of the Dattus meter by the Binder Connector. The module is seated into the
bracket to create a secure assembly.
Vertical installation Horizontal installation
Connecting the 2.4GZ OpenWay Remote Mount Gas Module to a
Dattus meter
The Dattus fM2 and fM3 meters have two configurable outputs usable as pulse outputs to the 2.4GZ
OpenWay remote mount gas module. Connecting the endpoint following the information in this section
requires a pulse output cable, installed at the Owenton, Kentucky Itron location. Pulse output cables are
available in 10 foot and 20 foot lengths. Factory-installed cables have a Binder connector on one end and six
bare wires on the opposite end.
Dattus Meter Wiring Accessories (available from Itron, Owenton, Kentucky)
Accessory
Itron Part Number
Pulse output cable - 10 ft.
442461-009
Pulse output cable - 20 ft.
442461-010
Pulse output cable
To wire the 2.4GZ to the Dattus meter
Pulse Output Cable Pin Descriptions
To use Output 3
To use Output 4
Pin
Function
Wire color
2.4GZ wire color
2.4GZ wire color
1
Cut cable
White
Blue
2
Output 4 (+)
Black
White
3
Ground (-)
Green
Red
4
Output 3 (+)
Orange
White
5
Cut cable
Red
Blue