User's Manual Part 2

Curb Diaphragm Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 82
Proprietary and Confidential
To program the 2.4GZ OpenWay remote mount gas module
1. Program the meter drive rate into the 2.4GZ OpenWay remote mount gas module using the handheld
computer and Belt Clip Radio. Programming parameters are based on the configuration file loaded into
the handheld computer.
2. Place the magnet over the barcode on the module cover label with the magnet face (inked Itron logo and
part number) arrow pointed up toward the top of the module.
3. Hold the magnet in place for 5 seconds and remove it.
4. The LED will blink red three times. This signifies the 2.4GZ OpenWay remote mount gas module is
searching for a programming device. Within a few seconds of locating the handheld computer, the red
LED will blink five more times. The handheld computer will confirm programming success or failure.
5. Read the 2.4GZ OpenWay remote mount gas module using the handheld computer and Belt Clip Radio.
If the read result is higher than the number programmed in Step 1, the 2.4GZ OpenWay remote mount
gas module is counting correctly.
If the read result is not higher than the number programmed in Step 1, replace the 2.4GZ OpenWay
remote mount gas module.