Curb Diaphragm Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 80
Proprietary and Confidential
3. Route the encoder cable through the index mounting screw inset to ensure adequate clearance for the
index cover and minimize pulling or twisting on the encoder. Continue routing the cable through the cable
inset on the Itron index cover to provide strain relief. Verify the strain-relief cable tie on the encoder cable
is inside the index cover before tightening the index cover screws.
4. Install the four index cover screws and tighten in an alternating fashion. Install the tamper seals included
in the American Meter Curb Installation kit.
2.4GZ OpenWay remote mount gas module encoder/index installation on the curb meter is complete.