User's Manual Part 2

Curb Diaphragm Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 79
Proprietary and Confidential
19. Program the index reading (with the encoder mounted) into the 2.4GZ OpenWay remote mount gas
module.
20. Read the 2.4GZ OpenWay remote mount gas module. If this reading is the same as the reading
programmed into the 2.4GZ OpenWay remote mount gas module, the module is programmed correctly.
To install the meter index covers over the 2.4GZ OpenWay remote mount gas module
encoder cable
1. Align the index wriggler (1) with the meter's drive dog (2). Install the index on the meter using the index
mounting screws. Tighten in an alternating fashion.
2. Install a strain-relief cable tie about one 1/4-inch from the encoder cable's stripped end (1). Remove the
excess cable tie with a side-cutting pliers (2). Dispose the excess cable tie properly.