User's Manual Part 2

Curb Diaphragm Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 78
Proprietary and Confidential
IMPORTANT You must do the next two steps exactly as described or the 2.4GZ OpenWay remote
mount gas module will not work properly.
16. Press the curved side of the encoder firmly against the side of the encoder spacing tool as shown below,
with the adhesive side down.
17. Slide the encoder down along the side of the encoder spacing tool until it touches the surface of the index
(as shown below). Using moderate pressure, hold the encoder firmly against the index, without moving,
for 15 seconds to permanently apply the encoder.
The photo below shows how the encoder spacing tool and encoder will look after the 15 second wait time.
18. Remove the encoder spacing tool, set it aside, and lay the index on a flat, horizontal surface, to diminish
strain on the encoder cable.