User's Manual Part 2
Curb Diaphragm Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 76
Proprietary and Confidential
8. Align the pointer (1) on the top of the magnet hub and the notch (2) in the side of the magnet hub with the
needle (3) of the meter drive rate dial.
9. Press the magnet hub down over the hub spacer as far as possible. The bottom of the hub spacer may
touch the index face. If the tip of the dial needle sticks out past the edge of the magnet hub, cut off the end
of the dial needle as close as possible to the magnet hub with a sharp, side-cutting pliers. Turn the dial
after magnet hub installation to verify the index dial functions with a smooth, easy rotation.
10. Take the acetone stick applicator from the Remote Encoder Installation Kit (Itron part number CFG-0081-
001).
11. Select a location on the index face next to the magnet hub. After encoder installation, the encoder cable
must not interfere with the index dials.
Note If a TEMP COMP sticker is attached to the index where the encoder cable will mount, remove it
before cleaning with the acetone stick. If the sticker (or replacement sticker) must be put back on the
register face, place it in a new location on the index face after the encoder is attached.
12. Tilt the acetone stick vertically with the wick end down. Squeeze the acetone stick on the black dot until
the packet inside the pen breaks. Continue to hold acetone stick vertical until the acetone wicks into the
foam applicator end.