User's Manual Part 2
Curb Diaphragm Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 75
Proprietary and Confidential
3. Briefly place the magnet side of the magnet hub into the curved indentation in the encoder, as shown.
4. Take the magnet hub away from the encoder and set it at least one inch away from the encoder.
5. Use the FC200 to read the 2.4GZ OpenWay remote mount gas module. If this reading is higher than the
reading taken after removing the index, the 2.4GZ OpenWay remote mount gas module is counting and
working properly.
Note If the reading is not higher than the previous reading, the 2.4GZ OpenWay remote mount gas
module is not reading. Repeat steps 3, 4, and 5. If the 2.4GZ OpenWay remote mount gas module is still
not counting, replace the 2.4GZ OpenWay remote mount gas module and perform steps 3, 4, and 5.
6. Align the large notch in the side of the magnet hub spacer with the needle of the meter drive rate dial (2
foot).
7. Press the magnet hub spacer down over the dial needle as far as possible. The tip on the bottom of the
spacer may touch index face. Turn the dial after hub spacer installation to verify the index dial functions
with a smooth, easy rotation.