User's Manual Part 2

Curb Diaphragm Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 74
Proprietary and Confidential
To remove the index
Note Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover
materials. Do not leave materials on customer premises. Replace any stripped, worn, or corroded
mounting screws.
1. Cut and remove any wire seal routed through the index cover screws. Remove the index cover and
dispose. Remove the index mounting screws in an alternating fashion.
2. Remove the two index screws in an alternating fashion.
Loosen the left index screw two turns.
Loosen the right index screw three to four turns. Finish removing the index holding screw.
Hold the index while removing the screws to keep the index from falling.
Set the index aside where it will not be damaged.
3. Use the FC200 or FC300 to read the 2.4GZ OpenWay remote mount gas module and record the reading
for comparison with progressive readings as installation is completed.
To install the encoder
1. Take the magnet hub from the Encoder Installation kit (Itron part number CFG-0081-001).
2. Verify there is only one magnet in the hub.
Note If there is no magnet or if there are two magnets in the magnet hub, discard the magnet hub and use
a hub with one magnet.