User's Manual Part 2

Diaphragm Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 66
Proprietary and Confidential
To install the meter index covers over the 2.4GZ OpenWay remote mount gas module
encoder cable
Note Use the correct replacement index cover gasket for your index (see Replacement Gaskets on page
58 for Itron 4-hole, 2-hole, or 1-hole gasket part numbers).
1. Remove the gasket center and index cover hole plugs from the new gasket.
2. Insert the index/encoder assembly through the gasket center. Verify the gasket's adhesive-backed side is
facing the meter face.
3. Align the index wriggler with the meter's drive dog. Install the index on the meter using the index
mounting screws. Tighten in an alternating fashion.
4. Install a strain-relief cable tie about one 1/4" from the encoder cable's stripped end. (The cable tie must be
inside the index cover after the cover is installed on the meter.)