User's Manual Part 2
Diaphragm Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 65
Proprietary and Confidential
17. Press the curved side of the encoder firmly against the side of the encoder spacing tool as shown below,
with the adhesive side down.
18. Slide the encoder down along the side of the encoder spacing tool until it touches the surface of the index
(as shown below). Using moderate pressure, hold the encoder firmly against the index, without moving,
for 15 seconds to permanently apply the encoder.
The photo below shows how the encoder spacing tool and encoder will look after the 15 second wait time.
19. Remove the encoder spacing tool, set it aside, and lay the index on a flat, horizontal surface, to diminish
strain on the encoder cable.
20. Program the index reading (with the encoder mounted) into the 2.4GZ OpenWay remote mount gas
module.
21. Read the 2.4GZ OpenWay remote mount gas module. If this reading is the same as the reading
programmed into the 2.4GZ OpenWay remote mount gas module, the module is programmed correctly.