User's Manual Part 2
Diaphragm Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 64
Proprietary and Confidential
Note If a TEMP COMP sticker is attached to the index where the encoder cable will mount, remove it
before cleaning with the acetone stick. If the sticker (or replacement sticker) must be put back on the
register face, place it in a new location on the index face after the encoder is attached.
13. Tilt the acetone stick vertically with the wick end down. Squeeze the acetone stick on the black dot until
the packet inside the pen breaks. Continue to hold acetone stick vertical until the acetone wicks into the
foam applicator end.
14. Thoroughly apply acetone the area where the encoder will be installed. Do not touch the cleaned area of
the index face before the encoder is installed.
15. Slide the thin end of the encoder spacing tool down over the magnet hub.
16. Peel the strip of protective plastic off the adhesive side of the endpoint's encoder.
IMPORTANT You must do the next two steps exactly as described or the 2.4GZ OpenWay remote
mount gas module will not work properly.