User's Manual Part 2

Diaphragm Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 61
Proprietary and Confidential
3. Remove old gasket and any gasket residue from the meter and index cover.
4. Use the FC200 or FC300 to read the 2.4GZ OpenWay remote mount gas module and record the reading
for comparison with progressive readings as installation is completed.
To install the encoder
1. Take the magnet hub from the Encoder Installation kit ( Itron part number CFG-0081-001).
2. Verify there is only one magnet in the hub.
Note If there is no magnet or if there are two magnets in the magnet hub, discard the magnet hub and use
a hub with one magnet.
3. Briefly place the magnet side of the magnet hub into the curved indentation in the encoder, as shown.
4. Take the magnet hub away from the encoder and set it at least one inch away from the encoder.
5. Use the FC200 to read the 2.4GZ OpenWay remote mount gas module. If this reading is higher than the
reading taken after removing the index, the 2.4GZ OpenWay remote mount gas module is counting and
working properly.