User's Manual Part 2

Diaphragm Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 60
Proprietary and Confidential
Installing 2.4GZ OpenWay Remote Mount Gas Module Encoders
Caution To insure proper adhesion, the 2.4GZ OpenWay remote mount gas module encoder
must be installed at temperatures between 40° to 95° Fahrenheit.
There are four tasks when installing the 2.4GZ OpenWay remote mount gas module with an encoder on a
diaphragm meter:
Remove the index cover and any gasket residue.
Install the 2.4GZ OpenWay remote mount gas module encoder on the index.
Program the 2.4GZ OpenWay remote mount gas module.
Attach the index cover to the meter.
To remove the index
Note Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover
materials. Do not leave materials on customer premises. Replace any stripped, worn, or corroded
mounting screws.
1. Cut and remove any wire seal routed through the index cover screws. Remove the index cover and set
aside. Remove the index mounting screws in an alternating fashion.
2. Remove the two index screws in an alternating fashion. Loosen the left index screw two turns, loosen the
index screw three to four turns. Hold the index while removing the screws to keep the index from falling.
Set the index aside where it will not be damaged.