User's Manual Part 1

2.4GZ OpenWay Remote Mount Gas Module Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 2
Proprietary and Confidential
Programming Modes
The 2.4GZ OpenWay gas module is programmed or reprogrammed to Normal, Sleep, or Doze Mode as
defined in the configuration file. The table below describes these modes.
Mode
Description/Use Case
Radio
Metering
(counting)
How to Enter
this Mode
How to Exit this Mode
Normal
Normal Operating Mode. Used for
Field Programming when electric
meters are present or being
installed.
On
On
Mag Swipe or
Programmer
Programmer (can reprogram
to any mode specified)
Sleep
For Shipping or Storage of
modules
Uses the least amount of battery
current since the module does not
communicate with the electric
meter.
Off
Off
Programmer
Mag Swipe (to normal) or
Programmer (to specified)
Snooze
Pre-program modules and deploy
so they try to join the network
automatically when they are
installed in the field. The flow of
gas or Mag Swipe triggers the
module to change to Normal
Mode.
Off
On
Programmer
Mag Swipe (to normal)
Programmer (to specified) or
Count Increment (to normal)
Doze
Pre-program meters in factory and
deploy so they do not try to join
the network when installed (for
example, install gas before electric
OR in factory counts will be added
after programming and user does
not want the radio turned on).
Off
On
Programmer
Mag Swipe (to normal) or
Programmer (to specified)