User's Manual Part 1
Electronic Instrument Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 50
Proprietary and Confidential
3. Dresser ROOTS
®
IMC/W2 and MC2 cables are typically delivered with a cable tie installed. If the meter
cable does not include a cable tie, install a tie to the cable just below the exposed colored lead wires on the
cable insulation. Remove the excess cable tie using a hand-held sidecutter pliers. The cable tie performs as
a cable strain relief to mitigate the risk of destructive tension on the lead wires.
4. Tuck the three gel connectors and cable tie inside the endpoint housing, as shown. Position the cable tie as
shown by the arrow in the position schematic below.
5. Install the 2.4GZ OpenWay remote mount gas module backplate using the four screws previously
removed from the endpoint and a Torx T-15 screwdriver.
Important Verify the cable tie and gel connectors are inside the endpoint housing and the cable extends
out of the slot in the backplate. Torque the backplate mounting screws to 9-12 inch-pounds.