User's Manual Part 1

Electronic Instrument Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 49
Proprietary and Confidential
2. Insert the lead wires from the 2.4GZ OpenWay remote mount gas module into new 3M gel connectors
(Itron part number CON-0023-001) together with the same colored lead wire from the meter cable (see the
wiring table below) and crimp using a 3M hand-held crimping tool.
Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping
gel-connects. The crimping tool provides an even pressured crimp to make a secure connection. Apply
pressure for three seconds until the gel cap is fully crimped (collapsed) to allow time for the low viscosity
silicone-based gel to flow. If the silicone gel flows out of the crimped connector, avoid touching the gel.
Gel flowing from the connector provides environmental protection for the connection.
Note Do not strip lead wire prior to inserting the wire in the gel connector.
IMC/W2 to Remote Endpoint Wire Table
IMC/W2 Wire
Remote endpoint wire
Red
Red
White
White
Blue
Blue