User's Manual Part 1
Electronic Instrument Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 48
Proprietary and Confidential
Connecting the OpenWay Remote Mount Gas Module to the
Dresser ROOTS
®
IMC/W2 or MC2 Cable
You may ship the Itron 2.4GZ OpenWay remote mount gas module directly to Dresser ROOTS
®
Meters for a
factory-installed cable. If you connect the module to the meter using an existing cable purchased from Dresser
ROOTS
®
, complete the following cable installation procedure.
Caution The purchased cable must have a mating connector compatible with the IMC/W2
or MC2 receptacle. Dresser ROOTS
®
cables may be wired in different configurations for
specific applications. If necessary, contact Dresser ROOTS
®
Meters for wiring diagrams for
your specific application.
To connect the 2.4GZ OpenWay remote mount gas module to the IMC/W2 or MC2 cable
1. Remove the backplate (4 screws) from the 2.4GZ remote module and expose the endpoint lead wires. The
backplate and screws will be re-installed on the endpoint module later in this procedure so store them
(temporarily) in a safe, secure place.