Electronic Instrument Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 46
Proprietary and Confidential
To make TCI pulse connections
Note Connect one endpoint/channel to the alarm output if the endpoints are used on channels A and B.
Configuration for two endpoints connected to one TCI
Channel A
OWG-500x-504
TCI
White
Orange and brown
Red
Yellow
Blue
Blue (alarm)
Channel B
OWG-500x-504
TCI
White
White
Red
Green
Blue
White
1. Remove strain relief fitting by unscrewing from the gray adapter plate.
Note Do not remove the fitting's hex nut. Un-screw the entire fitting from the gray adapter plate. A tether
line is secured to the strain relief fitting. When the strain relief fitting is removed, the tether line pulls the
unterminated wires out of the adapter plate for access to the loose wires.
2. Loosen the strain relief fitting hex nut and remove the white plug from the center.
3. Place the strain relief fitting onto the field pulse cable.