User's Manual Part 1

Rotary Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 30
Proprietary and Confidential
Mounting the 2.4GZ OpenWay Remote Mount Module
Select an appropriate mounting location on adjacent piping close to the meter. Using the pipe bracket,
mounting plate and band clamps from the Remote Mount Kit (Itron part number CFG-0005-003), secure the
2.4GZ OpenWay remote mount gas module. Use the cable ties from the kit to secure any excess wire to the
piping (see Mounting the 2.4GZ Remote Mount Module on a Pipe on page 9).
Installing the 2.4GZ OpenWay Remote Mount Gas module to
the Romet Electronically Compensated Meter (ECM2
®
)
The Romet ECM2
®
meter has three Form "A" outputs that can be configured at the factory to provide any
combination of the following three outputs:
Uncorrected volume (UNC VOL)
Corrected volume (COR VOL)
Alarm
The pulse weight for the volumetric outputs is configured in SetUp Mode at Menu items>SET UNC OUT
and SET COR OUT. Since Setup Mode is fully configurable, the ECM2
®
module is universally adaptable
to all Romet TC meter bodies. Reference the Romet technical manual for specific details on the ECM2
®
.