5. Insert the meter cable through the slot on the module backplate. Install a cable tie to the meter cable
wire below the meter cable insulation to provide strain relief. Position the cable tie as shown in the
position schematic below.
6. Tuck the connectors and cable tie into the endpoint housing. Place backplate on the assembly and
tighten the four backplate screws using a size T-10 Torx screwdriver.
Important Verify the cable tie and gel connectors are inside the endpoint housing and the cable
extends out of the slot in the backplate. Torque the backplate mounting screws to 9 - 12 inch-pounds.
To install the 2.4GZ OpenWay remote mount gas module cable
1. Insert the plug on the cable connected to the module into the receptacle on the meter adapter plate.
2. Tighten the threaded collar on the plug onto the American Meter interface receptacle. Verify the