User's Manual Part 1
Rotary Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 28
Proprietary and Confidential
3. Separate the black, white, and blue wires for connection to the 2.4GZ OpenWay remote mount gas
module. Cut off the unused wires even with the outer covering (insulation).
Caution Do not strip the individual wires.
4. Connect the meter cable to the 2.4GZ OpenWay remote mount gas module using 3M gel-cap
connectors. Follow the wire connection table and wiring diagrams below. See Installation Prerequisites
on page 7 for appropriate 3M crimping tools.
Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for
crimping gel-connects. The crimping tool provides an even pressured crimp to make a secure
connection. Apply pressure for three seconds until the gel cap is fully crimped (collapsed) to allow time
for the low viscosity silicone-based gel to flow. If the silicone gel flows out of the crimped connector,
avoid touching the gel. Gel flowing from the connector provides environmental protection for the
connection.
American RPM Meter to 2.4GZ Remote Mount Module Wire Connections
American RPM Meter wire
2.4GZ remote mount module wire
Red
Red
White
White
Black
Blue