User's Manual Part 1
Rotary Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 27
Proprietary and Confidential
6. Attach the 4-pin male connector on the Elster American Meter adapter plate to the 4-pin female
connector inside the meter's tower. The connectors will slide together and latch.
7. Carefully push the connectors and wires into the meter tower housing.
8. Lubricate the o-ring with o-ring lubricant and install the o-ring on the adapter plate. Insert the adapter
plate into the tower and tighten the (2) 5 mm screws.
To connect the manufacturer cable to the endpoint
Note Connection to an Elster American Meter requires a cable interface compatible to an Elster
American Meter RPM rotary meter.
1. Trim the 2.4GZ OpenWay remote mount gas module wires to 3.5-inches.
2. Carefully strip the insulation covering from the meter cable (purchased from the meter manufacturer)
approximately 1-1/2-inces from the end.
Caution Do not cut through the individual wire insulation.