User's Manual Part 1
Rotary Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 26
Proprietary and Confidential
To install the 2.4GZ OpenWay remote mount gas module on an Elster American RPM
series meter
1. Remove the meter's top plate by removing the two (2) 5mm screws and carefully prying up on the plate.
The plate is secured with an o-ring seal. Remove the o-ring from the plate.
Caution If the o-ring is damaged during removal, obtain a replacement from Elster American Meter
Co.
2. Look into the meter tower and find the meter switch lead and connector (4-pin).
3. If the lead and connector are not visible or cannot be found, remove the four (4) 5mm mounting screws
and the register cover. The meter switch lead and connector will be visible inside the cover.
Note Save any meter tags. You will re-install them later in the installation process.
4. Feed the lead and connector into the register cover tower.
5. If you removed the register cover, replace the cover using the four (4) 5mm mounting screws.