User's Manual Part 1
Rotary Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 24
Proprietary and Confidential
Programming 2.4GZ OpenWay Remote Mount Gas Modules for
Dresser ROOTS
®
Rotary Meters
To program 2.4GZ OpenWay remote mount gas modules for use with Dresser ROOTS
®
rotary meters, use
the meter drive rates from the drive rate table in this section.
B3, LMMA & S3A CTR/TC Meter Pulse Rates for Remote Module
Programming
Caution Do not use these meter drive rates to program residential direct-drive or commercial direct-
drive modules. Use the information in the following tables to program 2.4GZ OpenWay remote mount
gas modules connected to Dresser ROOTS
®
rotary meters.
B3 CTR Meter Size
B3 CTR Meter Pulse Rate
LMMA CTR Meter Size
LMMA CTR Meter Pulse Rate
8C
10
1.5M
10
11C
10
3M
10
15C
10
5M
10
2M
10
7M
10
3M
10
11M
10
5M
10
16M
100
7M
10
23M
100
11M
10
38M
100
16M
100
56M
100
23M
100
102M
100
38M
100
56M
100
LMMA CTR Meter Size
LMMA CTR Meter Pulse Rate
LMMA TC Meter Size
LMMA TC Meter Pulse Rate
1.5M
10
1.5M
10
3M
10
3M
10
5M
10
5M
10
7M
10
7M
10
11M
10
11M
10
16M
100
16M
100
23M
100
38M
100
56M
100
102M
100