User's Manual Part 1

Rotary Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 23
Proprietary and Confidential
To connect the 2.4GZ OpenWay remote mount gas module cable assembly to the rotary
meter
Caution Verify the cable connector mates with the meter connector. Meter manufacturers use
different connector styles (types).
1. Align the large lug on the 2.4GZ OpenWay remote mount gas module connector with the large notch on
the meter connector.
2. Align the lock ring notches on the module cable connector with the pins on the meter connector.
3. Hold the lock ring on the module connector back and push the plug into the meter connector until it is
securely seated.
4. Turn the lock ring clockwise as far as it will go. You will feel it snap into place when it locks.
Warning To remove the module connector plug from the meter connector jack, push in on the lock
ring, turn the lock ring counterclockwise as far as possible, and pull out the plug body. Do not pull on
the module's connector cable.