User's Manual Part 1
Rotary Meter Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 21
Proprietary and Confidential
To connect the 2.4GZ OpenWay remote mount gas module to the rotary meter cable
1. Remove the backplate (4 screws) from the 2.4GZ OpenWay Remote and expose the module's lead
wires. The backplate and screws will be re-installed on the gas module later in this procedure so store
them (temporarily) in a safe, secure place.
2. Insert the lead wires from the 2.4GZ OpenWay remote mount gas module into new 3M gel connectors
(Itron part number CON-0023-001) together with the same colored lead wire from the meter cable (see
the wiring table below) and crimp using a 3M hand-held crimping tool.
Note Do not strip lead wire prior to inserting the wire in the gel connector.
Rotary Meter to Remote Module Wire Table
Rotary Meter Wire
Remote module wire
Red
Red
White
White
Blue
Blue