User's Manual Part 1

Mounting the 2.4GZ OpenWay Remote Mount Gas Module
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 11
Proprietary and Confidential
To mount the pipe bracket on a vertical pipe
Caution Vertical mounting position is important to maximize RF performance. You can mount
a 2.4GZ OpenWay remote gas module with the module's label arrow pointing up or down,
dependent upon the application as noted in relevant sections of this installation manual. The
module's arrow must never point to either side. The module's tilt tamper functionality is
designed to operate with the module installed vertically. The 2.4GZ module's tilt tamper will
operate with the label arrow pointed up or down. The module's tilt tamper will not operate with
the module installed horizontally (the label arrow pointed to either side).
1. Remove the pipe bracket and band clamp from the Remote Mount Installation Kit (Itron part number
CFG-0005-003).
2. Loosen the band clamp screw until the end of the band releases.
3. Push the end of the clamp's band (1) through the holes (2) in the pipe bracket. The pipe bracket must be
oriented as shown below.
4. Place the band clamp around the pipe. The band will loosely wrap around the pipe. Push the end of the
band through the band clamp screw assembly. Turn the band clamp's screw assembly to fit into the pipe
bracket opening. Tighten the clamp screw until the band clamp is secure on the pipe.
Caution The pipe bracket must fit firmly against the pipe to prevent slippage.