Mounting the 2.4GZ OpenWay Remote Mount Gas Module
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 9
Proprietary and Confidential
Mounting Installation Considerations
Select a proper mounting location. Itron recommends mounting the 2.4GZ OpenWay remote mount gas
module in close proximity to the meter or instrument. Some applications may require an extended cable-
length. The 2.4GZ OpenWay remote mount gas module supports cable lengths up to 300 feet.
Mount the 2.4GZ OpenWay remote mount gas module in a vertical position with the endpoint label
directional arrow pointed upward or downward.
Caution Vertical mounting position is important to maximize RF performance. You can
mount a 2.4GZ OpenWay remote gas module with the module's label arrow pointing up or
down, dependent upon the application as noted in relevant sections of this installation
manual. The module's arrow must never point to either side. The module's tilt tamper
functionality is designed to operate with the module installed vertically. The 2.4GZ
module's tilt tamper will operate with the label arrow pointed up or down. The module's tilt
tamper will not operate with the module installed horizontally (the label arrow pointed to
either side).
Warning Do not mount the 2.4GZ OpenWay remote mount gas module in an orientation
other than vertical (endpoint label arrow pointed upward or downward). Violating the
mounting orientation requirements will void the product warranty.